We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Distribution evaluation device.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Distribution evaluation device - List of Manufacturers, Suppliers, Companies and Products | IPROS GMS

Distribution evaluation device Product List

1~5 item / All 5 items

Displayed results

Evaluation of pore distribution in non-woven fabric sheets

Important analysis items for performance evaluation and quality control of functional materials! Evaluation of pore size and pore distribution of non-woven sheets and membrane materials.

This is an example of evaluating the maximum pore diameter and pore size distribution of non-woven fabric sheets using the bubble point method. The sample is immersed in a chemical solution and air pressure is applied. The pressure is increased until it overcomes the surface tension of the chemical solution absorbed in the sheet, resulting in the appearance of bubbles; this pressure is referred to as the bubble point. The maximum pore diameter can be calculated based on the bubble point pressure and the surface tension of the chemical solution. 【Calculation Formula】 ■d = Cy/P ・d: Maximum pore diameter ・C: Constant ・y: Surface tension of the chemical solution ・P: Differential pressure *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • Distribution evaluation device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Analysis Case] Evaluation of Carrier Distribution in Crystalline Si Solar Cells

Evaluation of carrier diffusion layer uniformity in samples with surface roughness.

This is an introduction to a case where the carrier diffusion layer distribution of the surface textured part and the back surface field (BSF) part of BSF-type crystalline silicon solar cells was evaluated using SCM. In the textured part, the pn junction is formed along the surface irregularities, while in the BSF part, it can be confirmed that the carrier distribution is interrupted and uneven.

  • 図5.png
  • 構造.png
  • SCM.png
  • 図2.png
  • 図3.png
  • Contract Analysis
  • Distribution evaluation device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Analysis Case] Evaluation of Carrier Density Distribution in Power Devices

Evaluation of the activation rate of the Dopant is possible.

SRA (Spreading Resistance Analysis) is a method that involves polishing a sample at an angle, making contact with two probes on the polished surface, and measuring the spreading resistance (Figure 1). By evaluating the carrier concentration distribution, it is possible to gain insights into the activation status of dopants. As an example, we present a case of SRA conducted on the central and outer regions of a diode chip surface after package opening (Figure 2).

  • Contract Analysis
  • Distribution evaluation device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Stress Load Testing Machine ISL-T300 + Birefringence Distribution Evaluation Device WPA-200

Real-time observation of orientation changes during the stretching of polymer films! Quantitative evaluation is possible as an in-plane distribution.

We would like to introduce the combination of the stress loading testing machine 'ISL-T300' and the birefringence distribution evaluation device 'WPA-200'. The change in molecular orientation due to the stretching of polymer films can be optically evaluated by measuring birefringence. However, it has been difficult to evaluate birefringence while simultaneously applying tension, especially as surface distribution information. With the proposed combination of devices, it is possible to quantitatively evaluate the orientation changes as a surface distribution during the stretching process. 【Device Specifications】 <ISL-T300> ■ Maximum Load: 300N ■ Travel Distance: Up to 30mm ■ Testing Speed: 0.08 to 8mm/min ■ Chuck Spacing: 2 to 32mm ■ Sample Thickness: 1.5mm or less *For more details, please refer to the PDF document or feel free to contact us.